{"id":38434,"date":"2026-06-09T11:26:00","date_gmt":"2026-06-09T04:26:00","guid":{"rendered":"https:\/\/vmts.ch\/fallstudie-punktwolke-zu-allplan-erich-kaestner-schule-fuessen\/"},"modified":"2026-06-09T14:41:59","modified_gmt":"2026-06-09T07:41:59","slug":"case-study-point-cloud-to-allplan-erich-kaestner-school-fuessen","status":"publish","type":"post","link":"https:\/\/vmts.ch\/en\/case-study-point-cloud-to-allplan-erich-kaestner-school-fuessen\/","title":{"rendered":"Point Cloud to Allplan \u2013 Erich-K\u00e4stner School F\u00fcssen: Case Study"},"content":{"rendered":"\n<div style=\"background:#000000;border-bottom:3px solid #C70100;margin-bottom:0;\">\n  <div style=\"display:grid;grid-template-columns:repeat(7,1fr) auto;gap:0;\">\n    <div style=\"padding:20px 18px 18px;border-right:0.5px solid #1a1a1a;\">\n      <div style=\"font-size:9px;font-weight:700;letter-spacing:.16em;text-transform:uppercase;color:#555;margin-bottom:5px;\">Project<\/div>\n      <div style=\"font-size:13px;color:#ccc;line-height:1.35;\"><strong style=\"color:#fff;\">Erich-K\u00e4stner School F\u00fcssen<\/strong><\/div>\n    <\/div>\n    <div style=\"padding:20px 18px 18px;border-right:0.5px solid #1a1a1a;\">\n      <div style=\"font-size:9px;font-weight:700;letter-spacing:.16em;text-transform:uppercase;color:#555;margin-bottom:5px;\">School Authority<\/div>\n      <div style=\"font-size:13px;color:#ccc;line-height:1.35;\">Ostallg\u00e4u District Office<\/div>\n    <\/div>\n    <div style=\"padding:20px 18px 18px;border-right:0.5px solid #1a1a1a;\">\n      <div style=\"font-size:9px;font-weight:700;letter-spacing:.16em;text-transform:uppercase;color:#555;margin-bottom:5px;\">Address<\/div>\n      <div style=\"font-size:13px;color:#ccc;line-height:1.35;\">Feistlestra\u00dfe 3<br>87629 F\u00fcssen, Bavaria<\/div>\n    <\/div>\n    <div style=\"padding:20px 18px 18px;border-right:0.5px solid #1a1a1a;\">\n      <div style=\"font-size:9px;font-weight:700;letter-spacing:.16em;text-transform:uppercase;color:#555;margin-bottom:5px;\">Building Type<\/div>\n      <div style=\"font-size:13px;color:#ccc;line-height:1.35;\">Special Needs Support Center<\/div>\n    <\/div>\n    <div style=\"padding:20px 18px 18px;border-right:0.5px solid #1a1a1a;\">\n      <div style=\"font-size:9px;font-weight:700;letter-spacing:.16em;text-transform:uppercase;color:#555;margin-bottom:5px;\">BIM Platform<\/div>\n      <div style=\"font-size:13px;color:#ccc;line-height:1.35;\"><strong style=\"color:#fff;\">Allplan<\/strong> (native)<\/div>\n    <\/div>\n    <div style=\"padding:20px 18px 18px;border-right:0.5px solid #1a1a1a;\">\n      <div style=\"font-size:9px;font-weight:700;letter-spacing:.16em;text-transform:uppercase;color:#555;margin-bottom:5px;\">LOD \/ Deliverables<\/div>\n      <div style=\"font-size:13px;color:#ccc;line-height:1.35;\">\n        <span style=\"display:inline-block;background:#C70100;color:#fff;font-size:10px;font-weight:700;letter-spacing:.06em;text-transform:uppercase;padding:2px 7px;margin-right:3px;\">LOD 300<\/span>\n        <span style=\"display:inline-block;background:#222;color:#fff;font-size:10px;font-weight:700;letter-spacing:.06em;text-transform:uppercase;padding:2px 7px;\">LOD 350*<\/span><br>\n        <span style=\"font-size:11px;color:#666;margin-top:3px;display:block;\">.prj \u00b7 IFC2x3 \u00b7 QC Report<\/span>\n      <\/div>\n    <\/div>\n    <div style=\"padding:20px 18px 18px;border-right:0.5px solid #1a1a1a;\">\n      <div style=\"font-size:9px;font-weight:700;letter-spacing:.16em;text-transform:uppercase;color:#555;margin-bottom:5px;\">Processing Time<\/div>\n      <div style=\"font-size:13px;color:#ccc;line-height:1.35;\"><strong style=\"color:#fff;font-size:18px;\">12<\/strong> Working Days<\/div>\n    <\/div>\n    <div style=\"padding:16px 18px;display:flex;align-items:center;justify-content:center;\">\n      <a href=\"https:\/\/vmts.ch\/online-formulare\/\" style=\"display:block;background:#C70100;color:#fff;font-size:10px;font-weight:700;letter-spacing:.1em;text-transform:uppercase;padding:10px 14px;text-decoration:none;white-space:nowrap;\">Request a Quote<\/a>\n    <\/div>\n  <\/div>\n<\/div>\n\n\n\n<nav style=\"background:#F5F5F5;border-left:3px solid #C70100;padding:20px 24px;margin-bottom:44px;\" aria-label=\"Table of Contents\">\n  <div style=\"font-size:10px;font-weight:700;letter-spacing:.16em;text-transform:uppercase;color:#4A4A4A;margin-bottom:14px;\">Table of Contents<\/div>\n  <div style=\"display:grid;grid-template-columns:1fr 1fr;gap:0 32px;\">\n    <ol style=\"list-style:none;counter-reset:toc;padding:0;margin:0;\">\n      <li style=\"counter-increment:toc;font-size:13px;margin-bottom:7px;padding-left:22px;position:relative;\"><span style=\"position:absolute;left:0;color:#C70100;font-weight:700;font-size:11px;\">1.<\/span><a href=\"#background\" style=\"color:#4A4A4A;text-decoration:none;\">The Starting Situation<\/a><\/li>\n      <li style=\"counter-increment:toc;font-size:13px;margin-bottom:7px;padding-left:22px;position:relative;\"><span style=\"position:absolute;left:0;color:#C70100;font-weight:700;font-size:11px;\">2.<\/span><a href=\"#native-modeling\" style=\"color:#4A4A4A;text-decoration:none;\">What Does &#8220;Native Allplan Modeling&#8221; Mean?<\/a><\/li>\n      <li style=\"counter-increment:toc;font-size:13px;margin-bottom:7px;padding-left:22px;position:relative;\"><span style=\"position:absolute;left:0;color:#C70100;font-weight:700;font-size:11px;\">3.<\/span><a href=\"#workflow\" style=\"color:#4A4A4A;text-decoration:none;\">The Workflow Step by Step<\/a><\/li>\n      <li style=\"counter-increment:toc;font-size:13px;margin-bottom:7px;padding-left:22px;position:relative;\"><span style=\"position:absolute;left:0;color:#C70100;font-weight:700;font-size:11px;\">4.<\/span><a href=\"#lod\" style=\"color:#4A4A4A;text-decoration:none;\">LOD Levels: What Was Realistic?<\/a><\/li>\n    <\/ol>\n    <ol style=\"list-style:none;counter-reset:toc 4;padding:0;margin:0;\">\n      <li style=\"counter-increment:toc;font-size:13px;margin-bottom:7px;padding-left:22px;position:relative;\"><span style=\"position:absolute;left:0;color:#C70100;font-weight:700;font-size:11px;\">5.<\/span><a href=\"#challenges\" style=\"color:#4A4A4A;text-decoration:none;\">Challenges in the Project<\/a><\/li>\n      <li style=\"counter-increment:toc;font-size:13px;margin-bottom:7px;padding-left:22px;position:relative;\"><span style=\"position:absolute;left:0;color:#C70100;font-weight:700;font-size:11px;\">6.<\/span><a href=\"#result\" style=\"color:#4A4A4A;text-decoration:none;\">Result and Deliverables<\/a><\/li>\n      <li style=\"counter-increment:toc;font-size:13px;margin-bottom:7px;padding-left:22px;position:relative;\"><span style=\"position:absolute;left:0;color:#C70100;font-weight:700;font-size:11px;\">7.<\/span><a href=\"#faq\" style=\"color:#4A4A4A;text-decoration:none;\">Frequently Asked Questions<\/a><\/li>\n      <li style=\"counter-increment:toc;font-size:13px;margin-bottom:7px;padding-left:22px;position:relative;\"><span style=\"position:absolute;left:0;color:#C70100;font-weight:700;font-size:11px;\">8.<\/span><a href=\"#contact\" style=\"color:#4A4A4A;text-decoration:none;\">Contact<\/a><\/li>\n    <\/ol>\n  <\/div>\n<\/nav>\n\n\n\n<div style=\"background:#000000;border-left:5px solid #C70100;padding:24px 28px 22px;margin-bottom:36px;\" role=\"note\" aria-label=\"Quick overview\">\n  <div style=\"font-size:10px;font-weight:700;letter-spacing:.18em;text-transform:uppercase;color:#C70100;margin-bottom:10px;\">What is Point Cloud to Allplan?<\/div>\n  <p style=\"font-size:14px;color:#ccc;line-height:1.65;margin-bottom:20px;\">\n    <strong style=\"color:#fff;\">Point Cloud to Allplan<\/strong> refers to the process of converting 3D laser scan data (point clouds) into a native BIM model in Allplan software. The result is a fully editable <code style=\"font-family:monospace;background:#1a1a1a;color:#e88;padding:1px 5px;font-size:13px;\">.prj<\/code> project file with parametric Allplan components, attributes, and a georeferenced project structure \u2013 ready to use for as-built documentation, renovation planning, and public tenders.\n  <\/p>\n  <div style=\"display:grid;grid-template-columns:repeat(4,1fr);gap:0;border-top:0.5px solid #222;padding-top:16px;\">\n    <div style=\"display:flex;flex-direction:column;gap:3px;padding-right:16px;border-right:0.5px solid #222;\">\n      <span style=\"font-size:20px;font-weight:700;color:#C70100;line-height:1;\">LOD 300<\/span>\n      <span style=\"font-size:11px;color:#666;line-height:1.35;\">Standard for as-built &amp; renovation<\/span>\n    <\/div>\n    <div style=\"display:flex;flex-direction:column;gap:3px;padding:0 16px;border-right:0.5px solid #222;\">\n      <span style=\"font-size:20px;font-weight:700;color:#C70100;line-height:1;\">12 WD<\/span>\n      <span style=\"font-size:11px;color:#666;line-height:1.35;\">Processing time in this project<\/span>\n    <\/div>\n    <div style=\"display:flex;flex-direction:column;gap:3px;padding:0 16px;border-right:0.5px solid #222;\">\n      <span style=\"font-size:20px;font-weight:700;color:#C70100;line-height:1;\">7<\/span>\n      <span style=\"font-size:11px;color:#666;line-height:1.35;\">Supported point cloud formats<\/span>\n    <\/div>\n    <div style=\"display:flex;flex-direction:column;gap:3px;padding-left:16px;\">\n      <span style=\"font-size:20px;font-weight:700;color:#C70100;line-height:1;\">\u00b1 15 mm<\/span>\n      <span style=\"font-size:11px;color:#666;line-height:1.35;\">Dimensional accuracy at LOD 300<\/span>\n    <\/div>\n  <\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\" style=\"border-top-width:0px;border-right-width:0px;border-bottom-width:0px;border-left-color:#C70100;border-left-width:3px;padding-left:22px\">\n<p style=\"font-size:17px;line-height:1.72\">Erich-K\u00e4stner School in F\u00fcssen \u2013 a Special Needs Support Center operated by the Ostallg\u00e4u District Office \u2013 was approaching a renovation project. The point cloud was already in place. What was missing was a fully editable, native Allplan BIM model. VMT Solutions took on this step: from quality verification of the scan data to on-schedule model delivery in 12 working days.<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"background\" style=\"border-bottom-color:#C70100;border-bottom-width:2px;margin-top:52px;margin-bottom:18px;padding-bottom:10px\"><span class=\"ez-toc-section\" id=\"The_Starting_Situation\"><\/span>The Starting Situation<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img class=\"lazyload\" decoding=\"async\" src=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%271920%27%20height%3D%271080%27%20viewBox%3D%270%200%201920%201080%27%3E%3Crect%20width%3D%271920%27%20height%3D%271080%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-orig-src=\"https:\/\/vmts.ch\/wp-content\/uploads\/2026\/06\/punktwolke-erich-kaestner-schule-fuessen-aerial.jpg\" alt=\"3D laser scan of Erich-K\u00e4stner School F\u00fcssen \u2013 point cloud of the school building\"\/><figcaption class=\"wp-element-caption\">Point cloud of the school building (E57 format) \u2013 source data for native Allplan modeling<\/figcaption><\/figure>\n\n\n\n<p>The commissioning surveying office had already fully captured Erich-K\u00e4stner School at Feistlestra\u00dfe 3 in F\u00fcssen using a 3D laser scanner. The building, a Special Needs Support Center under the authority of the Ostallg\u00e4u District Office, was documented for an upcoming renovation \u2013 precise scan data was fully available.<\/p>\n\n\n\n<p>The challenge lay not in data quality but in capacity: the internal <a href=\"https:\/\/vmts.ch\/en\/absorb-bim-project-peaks-surveying-firms\/\">BIM modeling capacity<\/a> at the surveying office was fully occupied with parallel projects. Without external support, delivery to the client would have been delayed. The building itself presented typical requirements of a layered public building stock:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Multiple building sections from different construction phases with varying floor heights<\/li>\n\n\n\n<li>Complex roof geometries over the main building and extensions<\/li>\n\n\n\n<li>Stair cores and connecting corridors with limited line of sight<\/li>\n\n\n\n<li>Exterior areas with access surfaces, ramps, and terrain model<\/li>\n<\/ul>\n\n\n\n<div style=\"background:#fff3f3;border-left:4px solid #C70100;padding:14px 18px;margin:20px 0;font-size:14px;line-height:1.6;\">\n  <strong style=\"color:#C70100;\">The problem:<\/strong> The point cloud was complete. What was missing was a native, directly usable Allplan BIM model \u2013 delivered on schedule, quality-assured, and to the accuracy required for a public tender.\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"native-modeling\" style=\"border-bottom-color:#C70100;border-bottom-width:2px;margin-top:52px;margin-bottom:18px;padding-bottom:10px\"><span class=\"ez-toc-section\" id=\"What_Does_%E2%80%9CNative_Allplan_Modeling%E2%80%9D_Mean\"><\/span>What Does &#8220;Native Allplan Modeling&#8221; Mean?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img class=\"lazyload\" decoding=\"async\" src=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%272049%27%20height%3D%271251%27%20viewBox%3D%270%200%202049%201251%27%3E%3Crect%20width%3D%272049%27%20height%3D%271251%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-orig-src=\"https:\/\/vmts.ch\/wp-content\/uploads\/2026\/04\/Section-Native-Modeling-vs-IFC-Import.jpg\" alt=\"Native Allplan modeling vs. IFC import \u2013 comparison of editability and workflow integration\"\/><figcaption class=\"wp-element-caption\">Native Allplan model vs. IFC import: the decisive difference in editability and seamless workflow integration<\/figcaption><\/figure>\n\n\n\n<p>The distinction is critical for the project because it marks a significant practical difference.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-border-color is-layout-flow wp-block-column-is-layout-flow\" style=\"border-color:#DADADA;border-width:1px;padding-top:20px;padding-right:22px;padding-bottom:20px;padding-left:22px\">\n<p class=\"has-text-color\" style=\"color:#9E9E9E;font-size:10px;font-weight:700;letter-spacing:0.14em;text-transform:uppercase\">IFC Import<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Model_from_another_platform\"><\/span>Model from another platform<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p style=\"font-size:13px\">A model is created in Revit or Archicad and exported as IFC. Allplan can open the file, but components are not parametric and attributes are not correctly linked.<\/p>\n\n\n\n<ul style=\"font-size:13px\" class=\"wp-block-list\">\n<li>No editable Allplan objects<\/li>\n\n\n\n<li>Significant rework required<\/li>\n\n\n\n<li>Incompatible attribute structure<\/li>\n\n\n\n<li>No Allplan project standard<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column has-black-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"background-color:#000000;padding-top:20px;padding-right:22px;padding-bottom:20px;padding-left:22px\">\n<p class=\"has-text-color\" style=\"color:#C70100;font-size:10px;font-weight:700;letter-spacing:0.14em;text-transform:uppercase\">Native in Allplan<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-text-color\" style=\"color:#ffffff\"><span class=\"ez-toc-section\" id=\"Directly_usable_prj_project_file\"><\/span>Directly usable .prj project file<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"has-text-color\" style=\"color:#aaaaaa;font-size:13px\">The model is built from the start in Allplan \u2013 with Allplan components, attributes, and the client&#8217;s project-specific folder structure.<\/p>\n\n\n\n<ul style=\"color:#aaaaaa;font-size:13px\" class=\"wp-block-list has-text-color\">\n<li>Fully editable Allplan objects<\/li>\n\n\n\n<li>No conversion effort<\/li>\n\n\n\n<li>Attribute structure per office standard<\/li>\n\n\n\n<li>Seamless integration into existing workflows<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<p>For the Ostallg\u00e4u District Office, which uses Allplan as its planning standard, a <a href=\"https:\/\/vmts.ch\/en\/point-cloud-to-bim-allplan-workflow-lod-native-modeling\/\">native Allplan model<\/a> was not optional \u2013 it was a prerequisite for design phases 3 to 5, tender documents, and coordination with contractors.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"workflow\" style=\"border-bottom-color:#C70100;border-bottom-width:2px;margin-top:52px;margin-bottom:18px;padding-bottom:10px\"><span class=\"ez-toc-section\" id=\"The_Workflow_Step_by_Step\"><\/span>The Workflow Step by Step<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img class=\"lazyload\" decoding=\"async\" src=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%271024%27%20height%3D%27554%27%20viewBox%3D%270%200%201024%20554%27%3E%3Crect%20width%3D%271024%27%20height%3D%27554%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-orig-src=\"https:\/\/vmts.ch\/wp-content\/uploads\/2026\/04\/workflow-allplan-1024x554.jpg\" alt=\"Point Cloud to Allplan workflow \u2013 Scan to BIM process steps from data intake to delivery\"\/><figcaption class=\"wp-element-caption\">Complete workflow: from point cloud verification to Allplan project delivery for Erich-K\u00e4stner School F\u00fcssen<\/figcaption><\/figure>\n\n\n\n<div style=\"margin:8px 0 24px;\">\n  <div style=\"display:grid;grid-template-columns:48px 1fr;gap:20px;margin-bottom:0;padding-bottom:28px;border-bottom:0.5px solid #DADADA;\">\n    <div style=\"display:flex;flex-direction:column;align-items:center;\">\n      <div style=\"width:48px;height:48px;background:#000;color:#fff;display:flex;align-items:center;justify-content:center;font-size:14px;font-weight:700;flex-shrink:0;\">1<\/div>\n      <div style=\"flex:1;width:2px;background:#DADADA;min-height:20px;\">&nbsp;<\/div>\n    <\/div>\n    <div style=\"padding:12px 0 0;\">\n      <strong style=\"display:block;font-size:15px;font-weight:700;color:#000;margin-bottom:8px;\">Data Intake and Quality Verification<\/strong>\n      <p style=\"font-size:14px;color:#4A4A4A;line-height:1.65;margin-bottom:8px;\">The delivered point cloud (format: E57) was thoroughly reviewed before modeling began \u2013 not only for format, but for complete coverage of all building areas.<\/p>\n      <ul style=\"padding-left:18px;font-size:14px;color:#4A4A4A;line-height:1.65;\">\n        <li>Completeness of all floors in main and auxiliary buildings<\/li>\n        <li>Registration quality between individual scans (tolerance &lt; 5 mm)<\/li>\n        <li>Critical areas: stair cores, connecting corridors, roof structures<\/li>\n        <li>Point density relative to the agreed LOD 300<\/li>\n      <\/ul>\n      <div style=\"background:#fff3f3;border-left:4px solid #C70100;padding:12px 16px;margin-top:12px;font-size:14px;line-height:1.6;\">\n        Coverage gaps were identified in two areas (utility shaft, basement section). These were communicated before modeling commenced.\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <div style=\"display:grid;grid-template-columns:48px 1fr;gap:20px;padding-bottom:28px;border-bottom:0.5px solid #DADADA;\">\n    <div style=\"display:flex;flex-direction:column;align-items:center;\">\n      <div style=\"width:48px;height:48px;background:#000;color:#fff;display:flex;align-items:center;justify-content:center;font-size:14px;font-weight:700;flex-shrink:0;\">2<\/div>\n      <div style=\"flex:1;width:2px;background:#DADADA;min-height:20px;\">&nbsp;<\/div>\n    <\/div>\n    <div style=\"padding:12px 0 0;\">\n      <strong style=\"display:block;font-size:15px;font-weight:700;color:#000;margin-bottom:8px;\">Coordinate System and Georeferencing<\/strong>\n      <p style=\"font-size:14px;color:#4A4A4A;line-height:1.65;\">The point cloud carried the surveying office&#8217;s coordinate system (ETRS89). This system was transferred directly into the Allplan project. The BIM model is therefore accurately positioned in both plan and elevation \u2013 relevant for subsequent combination with site plan documents and geodata from the District Office.<\/p>\n    <\/div>\n  <\/div>\n\n  <div style=\"display:grid;grid-template-columns:48px 1fr;gap:20px;padding-bottom:28px;border-bottom:0.5px solid #DADADA;\">\n    <div style=\"display:flex;flex-direction:column;align-items:center;\">\n      <div style=\"width:48px;height:48px;background:#000;color:#fff;display:flex;align-items:center;justify-content:center;font-size:14px;font-weight:700;flex-shrink:0;\">3<\/div>\n      <div style=\"flex:1;width:2px;background:#DADADA;min-height:20px;\">&nbsp;<\/div>\n    <\/div>\n    <div style=\"padding:12px 0 0;\">\n      <strong style=\"display:block;font-size:15px;font-weight:700;color:#000;margin-bottom:8px;\">Project Structure and Allplan Configuration<\/strong>\n      <p style=\"font-size:14px;color:#4A4A4A;line-height:1.65;\">Before modeling, the project structure was set up in Allplan: partial drawings per floor and building section, layer structure per office standard, attribute assignments for room designations and component properties. The configuration followed the requirements of the commissioning office.<\/p>\n    <\/div>\n  <\/div>\n\n  <div style=\"display:grid;grid-template-columns:48px 1fr;gap:20px;padding-bottom:28px;border-bottom:0.5px solid #DADADA;\">\n    <div style=\"display:flex;flex-direction:column;align-items:center;\">\n      <div style=\"width:48px;height:48px;background:#000;color:#fff;display:flex;align-items:center;justify-content:center;font-size:14px;font-weight:700;flex-shrink:0;\">4<\/div>\n      <div style=\"flex:1;width:2px;background:#DADADA;min-height:20px;\">&nbsp;<\/div>\n    <\/div>\n    <div style=\"padding:12px 0 0;\">\n      <strong style=\"display:block;font-size:15px;font-weight:700;color:#000;margin-bottom:8px;\">Modeling Based on the Point Cloud<\/strong>\n      <p style=\"font-size:14px;color:#4A4A4A;line-height:1.65;margin-bottom:8px;\">Modeling was carried out in Allplan with direct reference to the point cloud. The following components were captured within the LOD 300 scope:<\/p>\n      <ul style=\"padding-left:18px;font-size:14px;color:#4A4A4A;line-height:1.65;\">\n        <li><strong>Structure and architecture:<\/strong> External and internal walls, columns, slabs, roof structure (selected areas LOD 350), window and door openings with reveal details, stairs, ramps, parapets<\/li>\n        <li><strong>Exterior areas:<\/strong> Terrain model from point cloud data, access surfaces, ramps, exterior stairs<\/li>\n      <\/ul>\n      <p style=\"margin-top:10px;font-size:14px;color:#4A4A4A;line-height:1.65;\">Every component is based exclusively on measurable geometries from the point cloud \u2013 no interpolated or assumed dimensions.<\/p>\n    <\/div>\n  <\/div>\n\n  <div style=\"display:grid;grid-template-columns:48px 1fr;gap:20px;padding-bottom:28px;border-bottom:0.5px solid #DADADA;\">\n    <div style=\"display:flex;flex-direction:column;align-items:center;\">\n      <div style=\"width:48px;height:48px;background:#000;color:#fff;display:flex;align-items:center;justify-content:center;font-size:14px;font-weight:700;flex-shrink:0;\">5<\/div>\n      <div style=\"flex:1;width:2px;background:#DADADA;min-height:20px;\">&nbsp;<\/div>\n    <\/div>\n    <div style=\"padding:12px 0 0;\">\n      <strong style=\"display:block;font-size:15px;font-weight:700;color:#000;margin-bottom:8px;\">Quality Control and QC Report<\/strong>\n      <p style=\"font-size:14px;color:#4A4A4A;line-height:1.65;margin-bottom:8px;\">After modeling was complete, the Allplan model was systematically checked back against the point cloud. A QC report (PDF) documents:<\/p>\n      <ul style=\"padding-left:18px;font-size:14px;color:#4A4A4A;line-height:1.65;\">\n        <li>Dimensional accuracy (target value \u00b1 15 mm for LOD 300, achieved)<\/li>\n        <li>Areas with point cloud gaps and assumptions made<\/li>\n        <li>Notes on special areas of the roof geometry (LOD 350)<\/li>\n      <\/ul>\n    <\/div>\n  <\/div>\n\n  <div style=\"display:grid;grid-template-columns:48px 1fr;gap:20px;\">\n    <div style=\"width:48px;height:48px;background:#000;color:#fff;display:flex;align-items:center;justify-content:center;font-size:14px;font-weight:700;flex-shrink:0;\">6<\/div>\n    <div style=\"padding:12px 0 0;\">\n      <strong style=\"display:block;font-size:15px;font-weight:700;color:#000;margin-bottom:8px;\">Delivery<\/strong>\n      <p style=\"font-size:14px;color:#4A4A4A;line-height:1.65;margin-bottom:8px;\">Deliverables after 12 working days:<\/p>\n      <ul style=\"padding-left:18px;font-size:14px;color:#4A4A4A;line-height:1.65;\">\n        <li>Allplan project file (.prj) in the version used by the client<\/li>\n        <li>IFC export (IFC2x3) for interdisciplinary exchange<\/li>\n        <li>QC report as PDF<\/li>\n        <li>Brief documentation of the project structure<\/li>\n      <\/ul>\n    <\/div>\n  <\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"lod\" style=\"border-bottom-color:#C70100;border-bottom-width:2px;margin-top:52px;margin-bottom:18px;padding-bottom:10px\"><span class=\"ez-toc-section\" id=\"LOD_Levels_What_Was_Realistic_in_This_Project\"><\/span>LOD Levels: What Was Realistic in This Project?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img class=\"lazyload\" decoding=\"async\" src=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%271024%27%20height%3D%27683%27%20viewBox%3D%270%200%201024%20683%27%3E%3Crect%20width%3D%271024%27%20height%3D%27683%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-orig-src=\"https:\/\/vmts.ch\/wp-content\/uploads\/2026\/04\/lod-300-vs-lod-400-1024x683.jpg\" alt=\"LOD 300 vs. LOD 400 comparison \u2013 accuracy levels in Allplan Scan to BIM\"\/><figcaption class=\"wp-element-caption\">LOD comparison in the project: standard areas at LOD 300, roof details at LOD 350<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>LOD<\/th><th>Content<\/th><th>Typical Use Case<\/th><th>In This Project<\/th><\/tr><\/thead><tbody><tr><td><span style=\"display:inline-block;background:#DADADA;color:#4A4A4A;font-size:11px;font-weight:700;padding:2px 8px;letter-spacing:.06em;\">LOD 200<\/span><\/td><td>Mass components, no exact dimensions<\/td><td>Early phase, cost estimation<\/td><td>Not required<\/td><\/tr><tr><td><span style=\"display:inline-block;background:#C70100;color:#fff;font-size:11px;font-weight:700;padding:2px 8px;letter-spacing:.06em;\">LOD 300<\/span><\/td><td>Component-accurate geometry, real dimensions, complete openings<\/td><td>Design and approval planning, as-built documentation<\/td><td><strong>Project standard<\/strong><\/td><\/tr><tr><td><span style=\"display:inline-block;background:#9A0000;color:#fff;font-size:11px;font-weight:700;padding:2px 8px;letter-spacing:.06em;\">LOD 350<\/span><\/td><td>As LOD 300, plus connection details<\/td><td>Coordination model, interdisciplinary planning<\/td><td>Roof geometry (selected)<\/td><\/tr><tr><td><span style=\"display:inline-block;background:#000;color:#fff;font-size:11px;font-weight:700;padding:2px 8px;letter-spacing:.06em;\">LOD 400<\/span><\/td><td>Fabrication-level accuracy<\/td><td>Heritage preservation, industrial projects<\/td><td>Not included<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>For public school buildings and renovation projects, LOD 300 is the practical standard. It covers design phases 3 to 5 and delivers the accuracy required for tender documents and planning coordination. The roof areas of Erich-K\u00e4stner School were partially executed at LOD 350 due to their structural complexity.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"challenges\" style=\"border-bottom-color:#C70100;border-bottom-width:2px;margin-top:52px;margin-bottom:18px;padding-bottom:10px\"><span class=\"ez-toc-section\" id=\"Challenges_in_the_Project\"><\/span>Challenges in the Project<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img class=\"lazyload\" decoding=\"async\" src=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%271920%27%20height%3D%271080%27%20viewBox%3D%270%200%201920%201080%27%3E%3Crect%20width%3D%271920%27%20height%3D%271080%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-orig-src=\"https:\/\/vmts.ch\/wp-content\/uploads\/2026\/06\/allplan-dachgeometrie-lod350-erich-kaestner-schule.jpg\" alt=\"Complex roof geometry of the school \u2013 modeled in Allplan from point cloud\"\/><figcaption class=\"wp-element-caption\">Detail area: complex roof geometry over the extension of Erich-K\u00e4stner School \u2013 LOD 350, modeled from actual point cloud geometry<\/figcaption><\/figure>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-color:#C70100;border-top-width:3px;background-color:#F5F5F5;padding-top:18px;padding-right:20px;padding-bottom:18px;padding-left:20px\">\n<h3 class=\"wp-block-heading\" style=\"font-size:14px\"><span class=\"ez-toc-section\" id=\"Multi-Phase_Building_Stock\"><\/span>Multi-Phase Building Stock<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p style=\"font-size:13px\">Main building and extensions originate from different construction phases. Floor heights vary, and transition areas are not structurally uniform. Each connection point was individually analyzed and documented on the basis of the point cloud.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-color:#C70100;border-top-width:3px;background-color:#F5F5F5;padding-top:18px;padding-right:20px;padding-bottom:18px;padding-left:20px\">\n<h3 class=\"wp-block-heading\" style=\"font-size:14px\"><span class=\"ez-toc-section\" id=\"Roof_Structure_with_Deformations\"><\/span>Roof Structure with Deformations<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p style=\"font-size:13px\">Historic roof elements show settlement and deformation. The geometry was modeled on the basis of actual scan data \u2013 without geometric simplifications. Deviations are documented in the QC report.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-color:#C70100;border-top-width:3px;background-color:#F5F5F5;padding-top:18px;padding-right:20px;padding-bottom:18px;padding-left:20px\">\n<h3 class=\"wp-block-heading\" style=\"font-size:14px\"><span class=\"ez-toc-section\" id=\"Point_Cloud_Gaps_in_Technical_Areas\"><\/span>Point Cloud Gaps in Technical Areas<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p style=\"font-size:13px\">A utility shaft and a basement section were not fully captured in the point cloud. In these areas, plausible geometric assumptions were made and transparently noted in the QC report.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-color:#C70100;border-top-width:3px;background-color:#F5F5F5;padding-top:18px;padding-right:20px;padding-bottom:18px;padding-left:20px\">\n<h3 class=\"wp-block-heading\" style=\"font-size:14px\"><span class=\"ez-toc-section\" id=\"Version_Compatibility\"><\/span>Version Compatibility<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p style=\"font-size:13px\">Allplan projects are version-specific. The model was delivered in the Allplan version used by the commissioning office. The version number was agreed at the time of order placement.<\/p>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"result\" style=\"border-bottom-color:#C70100;border-bottom-width:2px;margin-top:52px;margin-bottom:18px;padding-bottom:10px\"><span class=\"ez-toc-section\" id=\"Result_A_Directly_Usable_Allplan_Model\"><\/span>Result: A Directly Usable Allplan Model<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>The surveying office received, after 12 working days, a complete native Allplan model of Erich-K\u00e4stner School F\u00fcssen that integrated into the Ostallg\u00e4u District Office&#8217;s planning workflow without any conversion or adaptation effort. A comparable scope was delivered for the <a href=\"https:\/\/vmts.ch\/en\/state-library-berlin-scan-to-bim\/\">State Library Berlin<\/a> \u2013 170,000 m\u00b2 as-built survey, native at LOD 300.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-border-color is-layout-flow wp-block-column-is-layout-flow\" style=\"border-color:#DADADA;border-width:0.5px;padding-top:16px;padding-right:16px;padding-bottom:16px;padding-left:16px\">\n<div style=\"display:flex;gap:14px;align-items:flex-start;\">\n  <div style=\"flex-shrink:0;width:32px;height:32px;background:#C70100;color:#fff;display:flex;align-items:center;justify-content:center;font-size:15px;font-weight:700;\">\u2713<\/div>\n  <div><strong style=\"display:block;font-size:13px;font-weight:700;color:#000;margin-bottom:3px;\">Direct use in Allplan<\/strong><span style=\"font-size:12px;color:#9E9E9E;\">No IFC imports, no re-linking of attributes<\/span><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column has-border-color is-layout-flow wp-block-column-is-layout-flow\" style=\"border-color:#DADADA;border-width:0.5px;padding-top:16px;padding-right:16px;padding-bottom:16px;padding-left:16px\">\n<div style=\"display:flex;gap:14px;align-items:flex-start;\">\n  <div style=\"flex-shrink:0;width:32px;height:32px;background:#C70100;color:#fff;display:flex;align-items:center;justify-content:center;font-size:15px;font-weight:700;\">\u2713<\/div>\n  <div><strong style=\"display:block;font-size:13px;font-weight:700;color:#000;margin-bottom:3px;\">Full editability<\/strong><span style=\"font-size:12px;color:#9E9E9E;\">Every component is a genuine Allplan object with all properties<\/span><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-border-color is-layout-flow wp-block-column-is-layout-flow\" style=\"border-color:#DADADA;border-width:0.5px;padding-top:16px;padding-right:16px;padding-bottom:16px;padding-left:16px\">\n<div style=\"display:flex;gap:14px;align-items:flex-start;\">\n  <div style=\"flex-shrink:0;width:32px;height:32px;background:#C70100;color:#fff;display:flex;align-items:center;justify-content:center;font-size:15px;font-weight:700;\">\u2713<\/div>\n  <div><strong style=\"display:block;font-size:13px;font-weight:700;color:#000;margin-bottom:3px;\">Reliable as-built documentation<\/strong><span style=\"font-size:12px;color:#9E9E9E;\">Suitable for renovation planning, approvals, and tendering<\/span><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column has-border-color is-layout-flow wp-block-column-is-layout-flow\" style=\"border-color:#DADADA;border-width:0.5px;padding-top:16px;padding-right:16px;padding-bottom:16px;padding-left:16px\">\n<div style=\"display:flex;gap:14px;align-items:flex-start;\">\n  <div style=\"flex-shrink:0;width:32px;height:32px;background:#C70100;color:#fff;display:flex;align-items:center;justify-content:center;font-size:15px;font-weight:700;\">\u2713<\/div>\n  <div><strong style=\"display:block;font-size:13px;font-weight:700;color:#000;margin-bottom:3px;\">Documented quality evidence<\/strong><span style=\"font-size:12px;color:#9E9E9E;\">QC report with deviation log and assumption documentation<\/span><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img class=\"lazyload\" decoding=\"async\" src=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%271920%27%20height%3D%271080%27%20viewBox%3D%270%200%201920%201080%27%3E%3Crect%20width%3D%271920%27%20height%3D%271080%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-orig-src=\"https:\/\/vmts.ch\/wp-content\/uploads\/2026\/06\/allplan-bestandsmodell-erich-kaestner-schule-fuessen-lod300.jpg\" alt=\"Completed Allplan BIM as-built model Erich-K\u00e4stner School \u2013 LOD 300 ready for delivery\"\/><figcaption class=\"wp-element-caption\">Delivery-ready Allplan as-built model of Erich-K\u00e4stner School F\u00fcssen (LOD 300) \u2013 directly usable for renovation planning and tendering<\/figcaption><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote has-background is-layout-flow wp-block-quote-is-layout-flow\" style=\"border-left-color:#C70100;border-left-width:5px;background-color:#000000;padding-top:32px;padding-right:40px;padding-bottom:32px;padding-left:40px\">\n<p class=\"has-text-color\" style=\"color:#C70100;font-size:10px;font-weight:700;letter-spacing:0.18em;text-transform:uppercase\">VMT Solutions<\/p>\n\n\n\n<p class=\"has-text-color\" style=\"color:#ffffff;font-size:19px;font-weight:700;line-height:1.45\">You scan \u2013 we support all downstream services, <span style=\"color:#C70100;\">from point clouds to native BIM models.<\/span><\/p>\n<\/blockquote>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"video-shortcode\"><iframe title=\"Allplan: modello BIM da nuvola di punti | Scan-to-BIM con VMTS\" width=\"1360\" height=\"765\" src=\"https:\/\/www.youtube.com\/embed\/VvH9lDWztZM?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"faq\" style=\"border-bottom-color:#C70100;border-bottom-width:2px;margin-top:52px;margin-bottom:18px;padding-bottom:10px\"><span class=\"ez-toc-section\" id=\"Frequently_Asked_Questions\"><\/span>Frequently Asked Questions<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<div data-wp-context=\"{ &quot;autoclose&quot;: false, &quot;accordionItems&quot;: [] }\" data-wp-interactive=\"core\/accordion\" role=\"group\" class=\"wp-block-accordion is-layout-flow wp-block-accordion-is-layout-flow\">\n<div data-wp-class--is-open=\"state.isOpen\" data-wp-context=\"{ &quot;id&quot;: &quot;accordion-item-1&quot;, &quot;openByDefault&quot;: false }\" data-wp-init=\"callbacks.initAccordionItems\" data-wp-on-window--hashchange=\"callbacks.hashChange\" class=\"wp-block-accordion-item is-layout-flow wp-block-accordion-item-is-layout-flow\">\n<h4 class=\"wp-block-accordion-heading\"><button aria-expanded=\"false\" aria-controls=\"accordion-item-1-panel\" data-wp-bind--aria-expanded=\"state.isOpen\" data-wp-on--click=\"actions.toggle\" data-wp-on--keydown=\"actions.handleKeyDown\" id=\"accordion-item-1\" type=\"button\" class=\"wp-block-accordion-heading__toggle\"><span class=\"wp-block-accordion-heading__toggle-title\">What is the difference between a native Allplan model and an IFC import?<\/span><span class=\"wp-block-accordion-heading__toggle-icon\" aria-hidden=\"true\">+<\/span><\/button><\/h4>\n\n\n\n<div inert aria-labelledby=\"accordion-item-1\" data-wp-bind--inert=\"!state.isOpen\" id=\"accordion-item-1-panel\" role=\"region\" class=\"wp-block-accordion-panel is-layout-flow wp-block-accordion-panel-is-layout-flow\">\n<p>A native Allplan model is built directly in Allplan using Allplan components, attributes, and a project-specific folder structure. It is fully editable and integrates into existing Allplan workflows without any additional effort. An IFC import contains geometry but no parametric Allplan objects \u2013 every modification requires significant rework and the attribute structure is not compatible.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div data-wp-class--is-open=\"state.isOpen\" data-wp-context=\"{ &quot;id&quot;: &quot;accordion-item-2&quot;, &quot;openByDefault&quot;: false }\" data-wp-init=\"callbacks.initAccordionItems\" data-wp-on-window--hashchange=\"callbacks.hashChange\" class=\"wp-block-accordion-item is-layout-flow wp-block-accordion-item-is-layout-flow\">\n<h4 class=\"wp-block-accordion-heading\"><button aria-expanded=\"false\" aria-controls=\"accordion-item-2-panel\" data-wp-bind--aria-expanded=\"state.isOpen\" data-wp-on--click=\"actions.toggle\" data-wp-on--keydown=\"actions.handleKeyDown\" id=\"accordion-item-2\" type=\"button\" class=\"wp-block-accordion-heading__toggle\"><span class=\"wp-block-accordion-heading__toggle-title\">Which point cloud formats does VMT Solutions process?<\/span><span class=\"wp-block-accordion-heading__toggle-icon\" aria-hidden=\"true\">+<\/span><\/button><\/h4>\n\n\n\n<div inert aria-labelledby=\"accordion-item-2\" data-wp-bind--inert=\"!state.isOpen\" id=\"accordion-item-2-panel\" role=\"region\" class=\"wp-block-accordion-panel is-layout-flow wp-block-accordion-panel-is-layout-flow\">\n<p>We work with all common formats: E57, RCP, LAS, FLS, LAZ, XYZ, and PTX. For proprietary formats, we recommend a pre-conversion by the surveying office.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div data-wp-class--is-open=\"state.isOpen\" data-wp-context=\"{ &quot;id&quot;: &quot;accordion-item-3&quot;, &quot;openByDefault&quot;: false }\" data-wp-init=\"callbacks.initAccordionItems\" data-wp-on-window--hashchange=\"callbacks.hashChange\" class=\"wp-block-accordion-item is-layout-flow wp-block-accordion-item-is-layout-flow\">\n<h4 class=\"wp-block-accordion-heading\"><button aria-expanded=\"false\" aria-controls=\"accordion-item-3-panel\" data-wp-bind--aria-expanded=\"state.isOpen\" data-wp-on--click=\"actions.toggle\" data-wp-on--keydown=\"actions.handleKeyDown\" id=\"accordion-item-3\" type=\"button\" class=\"wp-block-accordion-heading__toggle\"><span class=\"wp-block-accordion-heading__toggle-title\">Which LOD is realistic for a public school building?<\/span><span class=\"wp-block-accordion-heading__toggle-icon\" aria-hidden=\"true\">+<\/span><\/button><\/h4>\n\n\n\n<div inert aria-labelledby=\"accordion-item-3\" data-wp-bind--inert=\"!state.isOpen\" id=\"accordion-item-3-panel\" role=\"region\" class=\"wp-block-accordion-panel is-layout-flow wp-block-accordion-panel-is-layout-flow\">\n<p>For as-built survey and renovation planning, LOD 300 is the practical standard. It covers design phases 3 to 5 and delivers component-accurate geometry, real dimensions, and complete openings. Selected areas can be extended to LOD 350 or LOD 400, depending on point cloud quality.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div data-wp-class--is-open=\"state.isOpen\" data-wp-context=\"{ &quot;id&quot;: &quot;accordion-item-4&quot;, &quot;openByDefault&quot;: false }\" data-wp-init=\"callbacks.initAccordionItems\" data-wp-on-window--hashchange=\"callbacks.hashChange\" class=\"wp-block-accordion-item is-layout-flow wp-block-accordion-item-is-layout-flow\">\n<h4 class=\"wp-block-accordion-heading\"><button aria-expanded=\"false\" aria-controls=\"accordion-item-4-panel\" data-wp-bind--aria-expanded=\"state.isOpen\" data-wp-on--click=\"actions.toggle\" data-wp-on--keydown=\"actions.handleKeyDown\" id=\"accordion-item-4\" type=\"button\" class=\"wp-block-accordion-heading__toggle\"><span class=\"wp-block-accordion-heading__toggle-title\">How long does it take to model a school building in Allplan?<\/span><span class=\"wp-block-accordion-heading__toggle-icon\" aria-hidden=\"true\">+<\/span><\/button><\/h4>\n\n\n\n<div inert aria-labelledby=\"accordion-item-4\" data-wp-bind--inert=\"!state.isOpen\" id=\"accordion-item-4-panel\" role=\"region\" class=\"wp-block-accordion-panel is-layout-flow wp-block-accordion-panel-is-layout-flow\">\n<p>This depends on size, complexity, and agreed LOD. The model of Erich-K\u00e4stner School F\u00fcssen was delivered in 12 working days. For new projects, we agree on a binding schedule after reviewing the point cloud.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div data-wp-class--is-open=\"state.isOpen\" data-wp-context=\"{ &quot;id&quot;: &quot;accordion-item-5&quot;, &quot;openByDefault&quot;: false }\" data-wp-init=\"callbacks.initAccordionItems\" data-wp-on-window--hashchange=\"callbacks.hashChange\" class=\"wp-block-accordion-item is-layout-flow wp-block-accordion-item-is-layout-flow\">\n<h4 class=\"wp-block-accordion-heading\"><button aria-expanded=\"false\" aria-controls=\"accordion-item-5-panel\" data-wp-bind--aria-expanded=\"state.isOpen\" data-wp-on--click=\"actions.toggle\" data-wp-on--keydown=\"actions.handleKeyDown\" id=\"accordion-item-5\" type=\"button\" class=\"wp-block-accordion-heading__toggle\"><span class=\"wp-block-accordion-heading__toggle-title\">How is the finished Allplan model delivered?<\/span><span class=\"wp-block-accordion-heading__toggle-icon\" aria-hidden=\"true\">+<\/span><\/button><\/h4>\n\n\n\n<div inert aria-labelledby=\"accordion-item-5\" data-wp-bind--inert=\"!state.isOpen\" id=\"accordion-item-5-panel\" role=\"region\" class=\"wp-block-accordion-panel is-layout-flow wp-block-accordion-panel-is-layout-flow\">\n<p>Delivery includes as standard the Allplan project file (.prj) in the version used by the client, an IFC export (IFC2x3) on request, and a QC report as PDF with dimensional accuracy verification. Data is delivered via the VMT Solutions client portal, WeTransfer, or a secure file transfer channel.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div data-wp-class--is-open=\"state.isOpen\" data-wp-context=\"{ &quot;id&quot;: &quot;accordion-item-6&quot;, &quot;openByDefault&quot;: false }\" data-wp-init=\"callbacks.initAccordionItems\" data-wp-on-window--hashchange=\"callbacks.hashChange\" class=\"wp-block-accordion-item is-layout-flow wp-block-accordion-item-is-layout-flow\">\n<h4 class=\"wp-block-accordion-heading\"><button aria-expanded=\"false\" aria-controls=\"accordion-item-6-panel\" data-wp-bind--aria-expanded=\"state.isOpen\" data-wp-on--click=\"actions.toggle\" data-wp-on--keydown=\"actions.handleKeyDown\" id=\"accordion-item-6\" type=\"button\" class=\"wp-block-accordion-heading__toggle\"><span class=\"wp-block-accordion-heading__toggle-title\">What is Scan to BIM for public buildings in Germany?<\/span><span class=\"wp-block-accordion-heading__toggle-icon\" aria-hidden=\"true\">+<\/span><\/button><\/h4>\n\n\n\n<div inert aria-labelledby=\"accordion-item-6\" data-wp-bind--inert=\"!state.isOpen\" id=\"accordion-item-6-panel\" role=\"region\" class=\"wp-block-accordion-panel is-layout-flow wp-block-accordion-panel-is-layout-flow\">\n<p>Scan to BIM for public buildings refers to the process of capturing an existing building with a 3D laser scanner and converting the point cloud data into a native BIM model. For municipal properties, schools, and administrative buildings in Bavaria and Germany, Allplan is frequently used as the BIM platform, as many public-sector clients use Allplan as their planning standard. VMT Solutions delivers these models at LOD 300 \u2013 ready for design phases 3 to 5, tender documents, and coordination with contractors.<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div id=\"contact\" class=\"wp-block-group has-black-background-color has-background is-content-justification-space-between is-layout-flex wp-container-core-group-is-layout-9da36aac wp-block-group-is-layout-flex\" style=\"border-left-color:#C70100;border-left-width:5px;background-color:#000000;padding-top:48px;padding-right:48px;padding-bottom:48px;padding-left:48px\">\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"has-text-color\" style=\"color:#C70100;font-size:10px;font-style:normal;font-weight:700;letter-spacing:0.16em;text-transform:uppercase\">Work with VMT Solutions<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-text-color\" style=\"color:#ffffff;font-size:26px;font-weight:400;line-height:1.25\"><span class=\"ez-toc-section\" id=\"Do_you_have_a_point_cloud_for_your_next_project\"><\/span>Do you have a point cloud for your next project?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"has-text-color\" style=\"color:#888888;font-size:14px\">Describe your project briefly using our online form. We will respond within one business day with an initial assessment \u2013 on schedule, transparent, and without any pre-commitment.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-text-color has-background has-custom-font-size wp-element-button\" href=\"https:\/\/vmts.ch\/online-formulare\/\" style=\"color:#ffffff;background-color:#C70100;font-size:13px;font-weight:700;letter-spacing:0.06em;text-transform:uppercase\">Request a Quote<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<p><\/p>\n\n","protected":false},"excerpt":{"rendered":"<p>Project Erich-K\u00e4stner School F\u00fcssen School Authority Ostallg\u00e4u District Office Address Feistlestra\u00dfe 387629 F\u00fcssen, Bavaria Building Type Special Needs Support Center BIM Platform Allplan (native) LOD \/ Deliverables LOD 300 LOD 350* .prj \u00b7 IFC2x3 \u00b7 [&#8230;]<\/p>\n","protected":false},"author":2,"featured_media":38436,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[387,481],"tags":[],"class_list":["post-38434","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-unkategorisiert-en","category-reference"],"acf":[],"_links":{"self":[{"href":"https:\/\/vmts.ch\/en\/wp-json\/wp\/v2\/posts\/38434","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vmts.ch\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/vmts.ch\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/vmts.ch\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/vmts.ch\/en\/wp-json\/wp\/v2\/comments?post=38434"}],"version-history":[{"count":4,"href":"https:\/\/vmts.ch\/en\/wp-json\/wp\/v2\/posts\/38434\/revisions"}],"predecessor-version":[{"id":38452,"href":"https:\/\/vmts.ch\/en\/wp-json\/wp\/v2\/posts\/38434\/revisions\/38452"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/vmts.ch\/en\/wp-json\/wp\/v2\/media\/38436"}],"wp:attachment":[{"href":"https:\/\/vmts.ch\/en\/wp-json\/wp\/v2\/media?parent=38434"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/vmts.ch\/en\/wp-json\/wp\/v2\/categories?post=38434"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/vmts.ch\/en\/wp-json\/wp\/v2\/tags?post=38434"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}